D (Was Model 833)
Standard Features
- Full Glass Tube Protection – 3-Sided Metal Frame with Clear Polycarbonate Shield
- Stainless Steel or Carbon Steel construction
- PVC Wetted Parts available
- Custom Lengths to customer specified center to center dimensions
- To achieve long lengths with higher glass pressure ratings, glass splicers may be installed
Specifications | |
---|---|
Wetted Materials | Plated CS, 316SS, or PVC |
Frame Materials | Plated CS or 304SS (304SS Frame for 316SS or PVC Wetted Materials Only) |
Seals | Fluorocarbon (standard), EPDM, FEP, Buna-N |
Connection Sizes | 1” to 2” (2”MNPT not available) |
Vessel Connection Types | MNPT, 150Lb & 300Lb ASME Flanges |
Tube Outer Diameter | 1” |
Center to Center Lengths | 12” to 180”+ (±1/8”) |
Automatic Ball Checks | None |
Vent & Drain | None |
Temperature Rating | Up to 400°F (Limited to Seal Ratings) |
Pressure Rating (Non-Steam) | Up to 600 PSIG |
Saturated Steam Rating | Up to 232 PSIG @ 400°F |
Shield/Scale Options
- Clear Protective Shield (no scale)
- Height Scale, Rate Scale, or Height and Rate Scale
- Expanded Metal Shield
Size & Connection Options
- See Matrix for full list
Tubing Options
- High Pressure Clear glass
- High Pressure Red Line glass (See Why Red Line)
- Heavy Wall Clear glass
- Heavy Wall Redline glass (See Why Red Line)
- Acrylic plastic
- Polycarbonate plastic
- FEP thermoplastic
- Red Floating Ball in tube
Application Notes:
- Saturated Steam Service: Acceptable when configured for saturated steam/water service
- Potable Water: Plated CS Gauges are not suitable for potable water. Gauges configured with all stainless steel wetted parts only are suitable for potable water
- Vacuum Service: Suitable with ball checks removed and no PTFE seals or FEP tubing is installed
- Gaseous Service: Not acceptable
- Compatibility: Before ordering, verify that all materials of our level gages are compatible with the service media(s), intermittently used cleaners, the environment, and cleaning processes in conjunction with the temperatures and pressures of the application(s) and future applications. John C. Ernst Co. does not make chemical compatibility recommendations. Compatibility is the responsibility of the user and/or specifying party.
WARNING: This product can expose you to certain chemicals, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to: www.P65Warnings.ca.gov
Replacement Parts:
- Please contact our Sales Dept. sales@ernstinstruments.com or 888-943-5000