OVAL GEAR METERS – 1/2" TO 2" FLANGED

SERIES GPI-OM
Oval Gear Meters - 1/2" to 2" Flanged

Meter Type
Positive Displacement (PD) Flow Meter designed to measure the flow of most fluids including high and varying viscosities without requiring recalibration.

How It Works
Positive Displacement Flow Meters measure the volumetric flow of fluids in pipes. As fluid flows through the chamber the oval gears rotate. Each rotation corresponds with a fixed volume of fluid that is picked up by a sensor creating a pulse signal. Electronic displays convert the pulse signal to a flow rate or totals.

Standard Features

  • High accuracy and repeatability, direct volumetric reading
  • No calibration required
  • Measures low and high viscosity liquids up to 1,000cps
  • Pressure rated up to 175 PSIG with 150Lb ASME Flanges
  • No straight pipe runs required up or downstream
  • Stainless Steel or Aluminum bodies
  • Bi-directional flow measurement
  • Factory Calibration Certificate supplied with each meter
  • 1 Year Limited Warranty

Optional Features

  • Measures up to 1,000,000cps
  • Quadrature pulse output option for high resolution
  • PF option for metering pulsating flows
  • Optional Exd I/IIB Approval (ATEX, IECEx)
  • Pressure rated up to 590 PSIG with 300Lb ASME Flanges

LCD Display Features

  • Rate of Flow, 2 Totals (1 Resettable Batch, 1 Cumulative)
  • User Configurable to GPM, LPM or any Unit of Measure
  • Factory Calibrated for 1.0 Specific Gravity
  • Field Calibratable for fluids greater than 1.0 Specific Gravity
  • Digital Display with 6 Digits Starting at 0.01 (floating decimal)
  • Totals Maximum of 99,999,999
  • Powered by 3.6V Battery (approximate 3 Year life, for display only) or may be externally powered

Electronic Options

  • Local or Remote LCD (see below features)
  • Pulse Output (Open Collector NPN)
  • 4-20mA Outputs
  • Scaled Pulse Output
  • Alarms or Batch Controlling

Specifications

Connection Sizes
1/2" (OM015)1" (OM025)1½" (OM040)2" (OM050)
FLOW RANGES*0.26 - 10.6 GPM (1 - 40 LPM)2.6 - 40 GPM (10- 150 LPM)4 - 68 GPM (15- 250 LPM)8 - 120 GPM (30- 450 LPM)
ACCURACY (Of Reading @ 3cps - 1000cps) 
Standard± 0.5%± 0.5%± 0.5%± 0.5%
With RT14 Display w/ non-linearity correction± 0.2%± 0.2%± 0.2%± 0.2%
REPEATABILITY (Typical)± 0.03%± 0.03%± 0.03%± 0.03%
PRESSURE RATINGS (With 150Lb ASME Flanges @ 140°F) 
Aluminum Meters (A)175 PSIG (12 Bar)175 PSIG (12 Bar)175 PSIG (12 Bar)175 PSIG (12 Bar)
Stainless Steel Meters (S)250 PSIG (17 Bar)250 PSIG (17 Bar)250 PSIG (17 Bar)250 PSIG (17 Bar)
Mechanical Aluminum Meters (M4)175 PSIG (12 Bar)175 PSIG (12 Bar)175 PSIG (12 Bar)175 PSIG (12 Bar)
Mechanical Stainless Steel Meters (M4)250 PSIG (17 Bar)250 PSIG (17 Bar)250 PSIG (17 Bar)250 PSIG (17 Bar)
TEMPERATURE RATINGS 
Meters with Pulse Out Only-4 to 250°F (-20 to 120°C)-4 to 250°F (-20 to 120°C)-4 to 250°F (-20 to 120°C)-4 to 250°F (-20 to 120°C)
Meters with LCD Display Only14 to 140°F (-10 to 60°C)14 to 140°F (-10 to 60°C)14 to 140°F (-10 to 60°C)14 to 140°F (-10 to 60°C)
Meters with LCD Display & 4-20mA Output32 to 140°F (0 to 60°C)32 to 140°F (0 to 60°C)32 to 140°F (0 to 60°C)32 to 140°F (0 to 60°C)
Meters with Mechanical Totalizer176°F (80°C)176°F (80°C)176°F (80°C)176°F (80°C)
VISCOSITY 
Standard Unit Ranges3 - 1,000 cps3 - 1,000 cps3 - 1,000 cps3 - 1,000 cps
Low Viscosities below 3cpsContact UsContact UsContact UsContact Us
High Viscosity Ranges1,000 - 1,000,000 cps1,000 - 1,000,000 cps1,000 - 1,000,000 cps1,000 - 1,000,000 cps
PRESSURE DROP (At Full Std Capacity)Contact UsContact UsContact UsContact Us
RECOMMENDED STRAINER SIZE100 Mesh (150 Microns)100 Mesh (150 Microns)100 Mesh (150 Microns)100 Mesh (150 Microns)
STRAIGHT PIPE REQUIREMENTSNoneNoneNoneNone
OUTPUT PULSE RESOLUTIONPulses per Gallon (Pulses per Liter) - nominal
Reed Switch318 PPG (84 PPL)102 PPG (27 PPL)53 PPG (14 PPL)25 PPG (6.5 PPL)
Hall Effect636 PPG (168 PPL)405 PPG (107 PPL)212 PPG (56 PPL)99 PPG (26 PPL)
QP-Quadrature Hall Option636 PPG (168 PPL)203 PPG (53.5 PPL)106 PPG (28 PPL)49 PPG (13 PPL)
SWITCH OUTPUTS 
Reed Switch Output30VDC x 200mA max. [Maximum Thermal Shock 50°F (10°C)/minute]
Hall Effect Output (NPN)3-Wire Open Collector, 5-24VDC Max. 20mA Max.
Optional Outputs4-20mA, Scaled Pulse, Quadrature Pulse, Flow Alarms or Two-Stage Batch Control
PROTECTION CLASSIP66/67 (NEMA4X), Optional Exd I / IIB T4/T6, Integral Ancillaries can be supplied I.S. (intrinsically Safe)
WETTED MATERIALS (Std) 
Body - Aluminum Meters (A)AluminumAluminumAluminumAluminum
Body - Stainless Steel Meter (S)316L Stainless Steel316L Stainless Steel316L Stainless Steel316L Stainless Steel
Bearings - Aluminum Meters (A)nonenonenonenone
Bearings - Stainless Steel Meters (S)Carbon CeramicCarbon CeramicCarbon CeramicCarbon Ceramic
Shaft - Aluminum & Stainless Steel MetersStainless SteelStainless SteelStainless SteelStainless Steel
Rotor - Aluminum Meters (A)PPSPPSPPSPPS
Rotor - Stainless Steel Meters (S)316 Stainless Steel316 Stainless Steel316 Stainless Steel316 Stainless Steel
Seals - Aluminum Meters (A)FKM (Viton™)FKM (Viton™)FKM (Viton™)FKM (Viton™)
Seals - Stainless Steel Meters (S)PTFE encapsulated FKMPTFE encapsulated FKMPTFE encapsulated FKMPTFE encapsulated FKM
CONN. TO CONN. LENGTH 
Aluminum Meters7.4" (188mm)7.8" (198mm)9.9" (251mm)10.9" (277mm)
Stainless Steel Meters7.4" (188mm)9.3" (236mm)9.9" (251mm)10.9" (277mm)

*Maximum flow is to be reduced as viscosity increases, see flow de-rating guide. Maximum recommended pressure drop is 15 PSIG (1.03 bar)

Options

  • PTFE encapsulated FKM (Viton™) Seals
  • Buna-N (Nitrile) Seals (-40°F minimum)
  • EPR (Ethylene Propylene Rubber) Seals for keytones (1/2” only)
  • High Viscosity SS or PPS Rotors
  • Up to 300°F rated
  • Sanitary Fittings (1/2″ size larger than meter size; for standard SS & Aluminum bodies)
  • 300Lb ASME Flanges (for standard SS & Aluminum bodies)
  • PN16 DIN Flanges (for standard SS & Aluminum bodies)
  • N.I.S.T. Certification

Replacement Parts

  • Contact our Sales Dept.

Alternate Meters

Application Notes

  • Saturated Steam Service: Not acceptable
  • Potable Water: Not acceptable.
  • Vacuum Service: Not acceptable
  • Gaseous Service: Not acceptable
  • General Non-Suitable Services: Liquids with unfiltered solids. Note that deionized (DI) and ultra-pure waters require all stainless steel components and PTFE seals.
  • Installation: Limit display’s exposure to sun.
  • Corrosion: Before ordering, verify all materials of our flow meters are compatible with the service media(s), intermittently used cleaners, the environment, and cleaning processes in conjunction with the temperatures and pressures of the application(s) and future applications. John C. Ernst Co. does not make chemical compatibility recommendations. Compatibility is the responsibility of the user and/or specifying party.

Model Number Matrix
Model Number Matrix