DIFFERENTIAL PRESSURE FLOW METERS - DIGITAL

SERIES M12
Digital Display Flow Rate & Totalization

(Was Model 300, 302), (Was Model 300W-RW3, 302W-RW3)

Meter Type
Differential Pressure/Flow Meter for fluids or gases
 
How It Works
Measures flow based on pressure differential created across a built-in nozzle
 

Features

  • LCD UV Resistant Display
  • Displays Rate, Total, and Accumulated Total
  • 2-Wire Loop Powered 4-20mA DC
  • Scaled Pulse
  • FNPT or Wafer Flange Design (fits between (2) 150 Lb or 300 Flanges)
  • Factory calibrated for Liquid or Gas
  • CE Rated

Applications

  • All 3 body materials are suitable for:
    • Water, most Oils & Solvents, and many low viscosity fluids
    • Compressed Air, Oxygen, Carbon Dioxide and many other non-toxic compressed gases
  • Monel is suitable for:
    • Sea Water and Brackish Water
    • Up to 25% Nitric Acid
  • Other acids and alkalines

*Always verify chemical compatibility with the body materials, the seals and all internal wetted parts
Sizes

  • 1/4″ to 8″

Detailed Specifications

Specifications
Digital Display Meters
DISPLAY INFO
Flow MeasurementsRate of Flow and Total
DisplayBacklight LCD 17mm (.67") and/or 8mm (.31")
Digit Size1/2"
No. of Digits for Flow Rate7
No. of Digits for Totalization11
Enclosure RatingIP67 / NEMA 4X
ACCURACY (Full Scale)±0.5%
PRESSURE
Standard Rating180 PSIG (12.4 Bar)
Optional Maximum Rating400 PSIG (27.5 Bar)
Minimum Required10 PSIG (0.69 Bar)
Standard Calibration for100 PSIG (6.9 Bar)
TEMPERATURE
Standard Rating178°F (80°C)
Minimum Rating-40°F (-40°C)
PRESSURE DROP
Bronze Meters at Full Scale5 PSIG (0.34 Bar)
High Pressure Meters (400 PSIG)7 PSIG (0.48 Bar)
Stainless & Monel Meters at Full Scale7 PSIG (0.48 Bar)
VISCOSITY
Standard Factory Calibration< 5cps
Optional Factory Calibration RequiredUp to 500cps
SPECIFIC GRAVITY
Standard Factory Calibration.95 - 1.05 S.G.
Optional Factory Calibration Required< 0.95 S.G. or > 1.05 S.G.
STRAIGHT PIPE REQUIREMENTS
Upstream (Pipe Diameters)10
Downstream (Pipe Diameters)0
ELECTRICAL
Current Output4-20mA
Power Input (Required by user)Loop Powered 24VDC, 100mA

Detailed Materials Of Construction

Materials Of Construction
Bronze316 Stainless Steel
WETTED MATERIALS (Standard)
BodyBronze316 Stainless Steel
SealsBuna-NBuna-N
BellowsBronze316 Stainless Steel
Cell CapsRyton®Ryton®
WETTED MATERIALS (Optional)
SealsViton®, EPR, TFEViton®, EPR, TFE
Bellows--
Cell CapsBronze, SSBronze, SS
NON-WETTED PARTS (Standard)
HousingGRP (Glass Reinforced Polyamide) with Polycarbonate Window
Gear MovementBronzeBronze (Opt'l Stainless Steel)

Detailed Standard Max. Flow Rate Scale GPM*

SizeStandard Max. Flow Rate Scale GPM*Conn. to Conn. LengthWeight
FNPTWaferFNPTWafer
1/4”2, 3, 43.06”4 Lbs
1/2” Low Flow4, 6, 10, 15, 20, 30, 40, 60, 100 GPH3.06”4 Lbs
1/2”2, 3, 4, 6, 103.06”1.12”4 Lbs4 Lbs
3/4”6, 10, 15, 203.06”1.12”4 Lbs5 Lbs
1”15, 20, 30, 403.06”1.12”4 Lbs5 Lbs
1-1/2”30, 40, 60, 1003.06”1.12”5 Lbs6 Lbs
2”40, 60, 100, 150, 2003.19”1.12”7 Lbs7 Lbs
2-1/2”60, 100, 150, 2001.12”8 Lbs
3”200, 300, 400, 5004.19”1.12”12 Lbs9 Lbs
4”300, 400, 500, 8001.12”12 Lbs
5”300, 400, 500, 8001.12”14 Lbs
6”600, 800, 1000, 20001.12”16 Lbs
8”600, 1000, 2000, 30001.12”24 Lbs

Detailed Flow Rate Scales

*Optional Flow Rate Scales:
LPM (Liquids), SCFM (Gases), Lbs/Hr (Steam)
Non-Standard Flow Rate Scales are available in up to 3 connection sizes below the standard scale of the connection size.
Please contact our Sales Dept. for pricing and to order.

 
Low Flow Range Scales

Standard Low-Flow Range Scales
LiquidGases
ScaleSizeGPHLPHCC/MSCFHNm³/h
11/2”.5 - 42 - 1530 - 2005 - 40.15 - 1
21/2”.5 - 63 - 2040 - 3005 - 60.3 - 2
31/2”1.5 - 105 - 4050 - 40015 - 100.4 - 3
41/2”2 - 155 - 6050 - 60020 - 150.5 - 4
51/2”3 - 2010 - 80150 - 100030 - 200.5 - 6
61/2”4 - 3015 - 120300 - 200040 - 3001 - 8
71/2”5 - 4020 - 150400 - 300050 - 4001.5 - 10
81/2”5 - 6030 - 240500 - 4000--
91/2”15 - 10050 - 400500 - 6000--

 
Standard Flow Range Scales

Standard Flow Range Scales
LiquidGasesSteam
ScaleThreadedWaferGPMLPMSCFMNm³/hLbs/Hr
A1/4” 1/2”1/2”.3 - 21 - 81.5 - 102 - 155 - 40
B1/4” 1/2”1/2”.4 - 32 - 153 - 204 - 305 - 60
C1/4” 1/2”1/2”.5 - 43 - 254 - 306 - 5010 - 80
D1/2” 3/4"1/2” 3/4".5 - 63 - 255 - 4010 - 8015 - 120
E1/2” 3/4"1/2” 3/4"1.5 - 105 - 405 - 6015 - 10030 - 200
F3/4” 1”3/4 ” 1”2 - 155 - 6020 - 15030 - 20040 - 300
G3/4” 1”3/4” 1”3 - 2010 - 8030 - 20040 - 30050 - 400
H1” 1½”1” 1½”4 - 3015 - 12040 - 30060 - 50050 - 600
I1” 1½” 2”1” 1½” 2”5 - 4020 - 15050 - 40050 - 600100 - 800
J1½” 2”1½” 2” 2½”5 - 6030 - 24050 - 600150 - 1000150 - 1000
K1½” 2”1½” 2” 2½”15 - 10050 - 400100 - 800150 - 1200300 - 2000
L2”2” 2½”20 - 15050 - 600150 - 1000200 - 1500400 - 3000
M2” 3”2” 2½” 3”30 - 200100 - 800150 - 1200300 - 2000500 - 4000
N3”3” 4” 5”40 - 300150 - 1000300 - 2000400 - 3000500 - 6000
O3”3” 4” 5”50 - 400200 - 1500400 - 3000600 - 50001000 - 8000
P3”3”50 - 500300 - 2000500 - 4000500 - 60001500 - 10000
Q4” 5” 6” 8”50 - 600300 - 2400600 - 500020 - 150 Nm³/m1500 - 10000
R4” 5” 6”100 - 800400 - 3000500 - 600030 - 200 Nm³/m2000 - 15000
S6” 8”150 - 1000500 - 40001000 - 800030 - 250 Nm³/m3000 - 20000
T6” 8“300 - 20001000 - 80002000 - 1500050 - 400 Nm³/m5000 - 40000
U8”400 - 30001500 - 120003000 - 2000050 - 600 Nm³/m5000 - 60000

 

Options

  • EPR, Viton®, Teflon® Seals
  • 350°F, 400 PSIG (120°F Max for Digital Meters)
  • LPM, SCFM, Nm³/H, Lbs/HR Scales
  • Factory Calibration for Stable Specific Gravities other than 1.0
  • Factory Calibration for Stable Viscosities under 500 cP
  • Non-Standard Flow Rates
  • Compressed Gas Service
  • Ammonia Service
  • Remote Readouts
  • Panel Mount Meter Case (1½” or smaller only)
  • 1 or 2 Reed switches SPDT
  • Two Set Point Relays (High/Low)
  • Cleaning for Oxygen Service
  • 24VDC Power Supply
  • NIST Calibration Certificates 4 to 200 GPM Full Scale up to Size 3″ (at time of order)
  • Expedited Shipping (please contact our Sales Dept.)
  • BSP Connections in Bronze or Stainless Steel

Application Notes

  • Saturated Steam Service: Not acceptable
  • Potable Water: Not acceptable
  • Vacuum Service: Not acceptable
  • Gaseous Service: Acceptable when configured for Gases
  • Installation: 10 pipe diameters of straight pipe required Upstream, No requirements downstream. Keep medias from freezing at all times in meter. Do not subject meter to water hammer. These Digital Meters require 24VDC power. We recommend that they are installed by an experienced installer or electrician.
  • Corrosion: Before ordering, verify all materials of our flow meters are compatible with the service media(s), intermittently used cleaners, the environment, and cleaning processes in conjunction with the temperatures and pressures of the application(s) and future applications. John C. Ernst Co. does not make chemical compatibility recommendations. Compatibility is the responsibility of the user and/or specifying party.

Replacement Parts

  • Please contact our sales department

Alternate Meters

ORDERING REQUIREMENTS FOR METERS IN NON-WATER APPLICATIONS

For Liquids Please Specify

  • Body Material: Bronze, 316SS
  • Seals: Buna-N, Ethylene Propylene, Viton®, or Teflon®
  • Connection Size: 1/4” to 8”
  • Flow Range: See Scale options
  • Flow Direction:
    • Horizontal Left to Right
    • Horizontal Right to Left
  • Media: If other than Water
  • Pressure: Between 10 PSIG to 400 PSIG
  • Temperature: Between -40 to 178°F
  • Specific Gravity: At normal operating temperature (If under .95 S.G. or over 1.05 S.G.)
  • Viscosity: At normal operating temperature (If over 5 cP)

For Gases Please Specify

  • Body Material: Bronze, 316SS
  • Seals: Buna-N, Ethylene Propylene, Viton®, or Teflon®
  • Connection Size: 1/4” to 8”
  • Flow Range: See Scale options
  • Flow Direction:
    • Horizontal Left to Right
    • Horizontal Right to Left
  • Gas: Name of gas
  • Pressure: Specify one specific or average pressure between 10 PSIG to 400 PSIG at meter inlet
  • Temperature: Specify one specific or average temperature between -40 to 178°F at meter inlet

Meter Head Mounting Options
Meter Head Mounting Options

Model Number Matrix
Model Number Matrix