(Was Model 31802V), (Was Model 31802VFL), (Was Model 31802VSP)
Meter Type
Economy Water Flowmeter, turbine type, battery powered that displays rate of flow and totals.
How It Works
Magnetic pulses are picked up by a coil. The computer converts the pulses into a flow rate and totals.
Standard Features
- Sch 80 PVC Body
- Rate of Flow, 2 Totals (1 Resettable Batch, 1 Cumulative)
- User Configurable to GPM, LPM or any Unit of Measure
- Factory Calibrated for 1.0 Specific Gravity
- Field Calibratable for fluids greater than 1.0 Specific Gravity
- Digital Display with 6 Digits Starting at 0.01 (floating decimal)
- Totals Maximum of 99,999,999
- Powered by (2) 1.5V AAA Alkaline Batteries (2-year life)
- Factory Calibration Certificate supplied with each meter
- Suitable for Water Cooling Systems, Waste Water, Irrigation, Batching
- Upgradeable to Remote Display, 4-20mA Output, Pulse Output (Open Collector NPN)
- CE & NSF Approved
- 1 Year Limited Warranty
Specifications
Size | ||
---|---|---|
3" | 4" | |
FLOW RANGES | ||
Standard | 40 - 400 GPM (151 - 1514 LPM) | 60 - 600 GPM (227 - 2271 LPM) |
Extended | 30 - 40 GPM, 400 - 600GPM (131 - 151 LPM, 1514 - 2271 LPM) | 40 - 60 GPM, 600 - 800 GPM (151 - 227 LPM, 2271 - 3028 LPM) |
ACCURACY | ||
Standard Range (Linearity Of Reading) | ± 3% | ± 3% |
Extended Range (Full Scale) | ± 2% | ± 2% |
PRESSURE RATING at 73°F | ||
Non CE Applications (All Models) | 225 PSIG (15.3 Bar) | 225 PSIG (15.3 Bar) |
CE Applications (All Models) | 135 PSIG (9.1 Bar) | 135 PSIG (9.1 Bar) |
Temperature Rating | 32°F to 140°F (0°C to 60°C) | 32°F to 140°F (0°C to 60°C) |
PRESSURE DROP | ||
At 400 GPM | 2.9 PSIG | 2.0 PSIG |
At 500 GPM | 4.9 PSIG | 3.0 PSIG |
At 700 GPM | - | 7.0 PSIG |
TYPICAL K-FACTOR | 43 PPG / 11 PPL | 17 PPG / 4.5 PPL |
STRAIGHT PIPE REQUIREMENTS | ||
Minimum Upstream | 30" (762mm) | 40" (1016mm) |
Minimum Downstream | 15" (381mm) | 20" (508mm) |
WETTED MATERIALS | ||
Body | PVC | PVC |
Bearings | PEEK | PEEK |
Shaft & Thrust Washers | Stainless Steel | Stainless Steel |
Rotor & Nose Cone | Acetal | Acetal |
Signal Generator | Ferrite | Ferrite |
Seals | n/a | n/a |
CONN. TO CONN. LENGTH | ||
NPT Threaded | 14.7" (373.4mm) | 17" (431.8mm) |
Flanged | 12" (304.8mm) | 14" (355.6mm) |
Spigot | 11.5" (292.1mm) | 13.5" (342.9mm) |
Optional Accessories
Alternate Meters
- Digital Series: GPI-OM (3-4″) Threaded, GPI-QSE, GPI-OM (3-4″) Flanged
- Analog Series: M12(NPT), M12(FLG)
Application Notes
- Saturated Steam Service: Not acceptable
- Potable Water: Yes – NSF Approved
- Vacuum Service: Not acceptable
- Gaseous Service: Not acceptable
- General Non-Suitable Services: Not acceptable for petroleum products, deionized (DI) or ultra-pure water applications. Not suitable for medias with varying viscosities.
- Installation: Do not allow media to freeze inside meter. Installation to metal connections is not recommended. Limit display’s exposure to sun.
- Corrosion: Before ordering, verify all materials of our flow meters are compatible with the service media(s), intermittently used cleaners, the environment, and cleaning processes in conjunction with the temperatures and pressures of the application(s) and future applications. John C. Ernst Co. does not make chemical compatibility recommendations. Compatibility is the responsibility of the user and/or specifying party.